while we are on the subject of pulses , ezra , will i damage my 200e using it with pulses from my 100? I believe the pulses on the 100 are in the 15 volt range ...
--- On Wed, 10/29/08, ezra buchla <ezra.buchla@gmail.com> wrote:
From: ezra buchla <ezra.buchla@gmail.com>
Subject: Re: [200e] Pulses and Gates
To: 200e@yahoogroups.com
Date: Wednesday, October 29, 2008, 4:44 PM
> I understand Buchla does pulses and gates differently than other mfg's.
the 200e uses a short (<10ms) onset pulse at 10v, and a 5v sustain
level, similar to 200 series but not always identical.
> I've never paid to much attention to the differences and have just gone
> about my business. I now plan on using a simple analog computer with
> my 200e
should be very straightforward
and I want to make sure that I understand the pulse and gate
> differences. At the very least, I have heard that "Buchla modules
> trigger on the falling edge of a gate." I'm not sure if that is true.
that should not be true. if it happens, it is a bug; i've had sporadic
reports of this but nothing specific enough for me to attempt to
verify.
[Non-text portions of this message have been removed]Message
Re: [200e] Pulses and Gates
2008-10-29 by joe Pascarell
Attachments
- No local attachments were found for this message.