Yahoo Groups archive

200e

Index last updated: 2026-04-28 22:38 UTC

Message

Re: Pulse in Stage Addressing

2009-12-20 by dougc356

Hi Ross, make sure that the cv input is fed by something changing at a different rate than the pulse input. If you happen to have a cv that is perfectly in time with the pulse timing, the 250e will sample the exact same value every pulse, and the stage will not change. 

Doug


--- In 200e@yahoogroups.com, ross healy <amni56@...> wrote:
>
> hi all
> 
> I am totally stumped by the Pulse in Stage Addressing. I put a pulse in 
> but it never seems to move the stages about? The CV works and if I patch 
> a pulse in to start adv it works?
> 
> Any ideas?
> 
> Thanks
> Ross
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.