oh a lovely surprise and loads of smiles to see you about here again yasi. ;-] On Nov 4, 2010, at 2:55 PM, cyaarsoil wrote: > to add and subtract numbers of pulses, > make the 250e have a 'retreat' pulse input (as opposed to 'advance'), > by setting the stage addressing to strobed, > and patching a CV output to stage adressing CV input, > and setting the voltage output from each stage to address the stage before. the strobe pulse input then acts as a 'retreat' input. > > then the current stage number is as an accumulator to which 'advance' pulses add and 'retreat' pulses subtract. have used this as a tempo difference meter comparing pulse frequency at 'advance' and 'retreat', and to synthesize signals at the tempo difference frequency. > > many variations > > also seems to suggest a few additions a sequencer might want...... > > had thought also of trying 256e in feedback around 266e sample and hold to do the adding and subtracting, but don't have the hardware at hand. > > Yasi Perera > > [Non-text portions of this message have been removed]
Message
Re: [200e] backwards going 250e
2010-11-05 by damon
Attachments