Witchole, Bruno, thanks for your ideas, but I think this is a non-starter. I set up some sysex strings in MIDI-OX last night to see what came back from the AN1x. F0 - Exclusive status 43 - Yam ID 20 - device number (0) preceded by '2', not 1 as with parameter change instructions 5C - model ID 00 - address high 00 - address mid 00 - address low F0 - end of Exclusive Any of the bulk dump addresses work fine and return a data dump, for example SYSTEM - 00 00 00 USER PATTERN - 01 00 00 CURRENT VOICE - 10 00 00 However, using addresses from the MIDI data table <1-2> returns nothing - unless they correspond with bulk dump instruction addresses - which I think shows that table <1-2> addresses can't be used to get parameter values, only to send them. Otherwise there would be a number of addresses which clash for the purposes of a dump request. For example, table <1-1> bulk request address 10 10 00 - Current Voice Scene 1 Buffer would clash with table <1-4> 10 10 00 - Poly mode if the other bytes around them were the same. If there are any MIDI wizards who can tell me I have it wrong and yes, you can get individual parameter values via sysex, I would love to hear it. But it doesn't look that way. Anyway, I'll push on with the TB MIDI Stuff editor and post any progress as I go. thanks again Bill --- In AN1x-list@yahoogroups.com, "witchole" <dougwoodrow@...> wrote: > > Interesting project! > This might be of some help: > http://www.jososoft.dk/yamaha/pdf/Beggar_SysExGuide.pdf > (although it's only specifically for Yamaha DB-50XG daughter boards). >