We're doing an instrument that needs to store a variable in EEPROM. It is a statistical certainty that, at some point, the power will fail just as the software starts to write the data. Any idea's how to handle this? Of course, we'll have the BOD enabled but I don't know (in fact really doubt) that it will save the day. Thanks, Tim Gilbert JEM Innovation Inc. 303-926-9053 (office) 303-437-4342 (cell) 720-890-8582 (fax) www.jeminnovation.com www.pdksolutions.com [Non-text portions of this message have been removed]
Message
EEPROM write and power failure
2008-04-28 by Tim Gilbert