>>When i used scope to check the output, i can see overshoot and undershoot > which are sometimes as big as the signal amplitude. > > When was the last time you compensated your scope probes? Do you have a > proper scope ground, ie. not a pigtail ground clip? > > See Linear Tech. AN92 for one example: > http://cds.linear.com/docs/Application%20Note/an92f.pdf > > Analog Devices has some good information in their seminar series of PDFs > as > well, > on proper measurement techniques. > > > -- > http://www.wearablesmartsensors.com/ > http://www.softwaresafety.net/ > http://www.designer-iii.com/ > http://www.unusualresearch.com/ > > > [Non-text portions of this message have been removed] > > I highly recommend the following Linear Tech application notes: Linear Circuits for Digital Systems: http://cds.linear.com/docs/Application%20Note/an31.pdf High Speed Amplifier Techniques (very highly recommended) http://cds.linear.com/docs/Application%20Note/an47fa.pdf Jim Wagner Oregon Research Electronics
Message
Re: [AVR-Chat] reducing signal overshoot/undershoot
2009-12-31 by wagnerj@proaxis.com
Attachments