On 12 Aug 2004 at 13:42, Dave VanHorn wrote:

> At 01:36 PM 8/12/2004, Bruce Parham wrote:
> 
> 
> >WTF! Who said anything about running it at 50 mA? I was using 10 mA
> >as the example, that's 2x minimum for the LED and in limit for the
> >AVR...
> 
> The guaranteed full on current is 50mA

I believe the data sheet is trying to say that the minimum required 
input current for 120mA output current at 25deg C is 5mA. I also 
believe that it is confusing to include the max figure of 50mA which 
is also the absolute maximum continuous input current. If you check 
the graphs on page 3, the typical switch on input current is less 
than 2mA.

I also note in the fine print "If both poles operate load current 
must be derated so as not to exceed the package power dissipation 
valve." I guess the "dissipation valve" is where the smoke comes out 
when you exceed the ratings! ;-)

Cheers,
Les Grant.

-------------------------------------------------------------
Les Grant. VK2KYJ.      Phone: 02 9896 7150 Fax: 02 9896 7153
Grantronics Pty Ltd     Int'l: +612 9896 7150, +612 9896 7153
ABN 46 070 123 643
PO Box 275, Wentworthville. NSW. 2145. Australia.            
http://www.grantronics.com.au  mailto:info@grantronics.com.au
Microcontroller Hardware and Software development:  Atmel AVR
8051 derivatives, 80C196 family, C, ASM, Digital and analogue 
-------------------------------------------------------------
Australian distributor for:
o Dunfield Development Systems low cost development tools
o ImageCraft AVR and Motorola Windows-hosted C compilers
o ELNEC Device Programmers (E)EPROMs, Flash, Micros, PLDs
o CAN-BUS Hardware and Software from LAWICEL
o Logical Systems Programming, Prototyping & Production Adaptors
-------------------------------------------------------------

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.