Yahoo Groups archive

AVR-Chat

Index last updated: 2026-04-28 22:41 UTC

Message

Re: [AVR-Chat] Mega8 reset problem

2004-09-09 by Mark Jordan

On 9 Sep 2004 at 3:17, Dave VanHorn wrote:

> 
> >
> >        But, if I apply an external reset, all goes back to normal.  
> >        A 100nF capacitor from RESET pin to ground solves the problem, too.
> >        Does the internal PowerOn Reset is not working on Timer2?
> >
> >        Any suggestions?
> 
> Do you fully init the timer, or do you leave some of the registers at
> defaults? 

	Fully init. Every register.
 
> 
> I've had problems in the past, initting SPI too soon after reset. This was an
> interaction with the device programmer, but you might be seeing something of
> that nature. 

	You hit the target!  
	I delayed the TIMER2 init sequence and it works ok now.  
	Thanks for the tip!

	Interesting that the problem is with TIMER2 only. The others aren't
affected. Maybe this is a PWM module issue.

	Mark Jordan