Re: Negative bias supply for signal conditioning op-amp

2005-03-31 by n1ist

Last time I needed a negative bias supply for a single opamp, I just 
grabbed it from the max232 I was using for the serial port.  If you 
have one of those in your circuit, it's a good source for +/-9V at 
limited current.