Yup, that CKOPT Fuse has caught everyone I know involved with AVRs. It personally gave me hours of grief trying to figure out why my micro would reset when doing UART Comms on a MEGA16. --- In AVR-Chat@yahoogroups.com, John Samperi <samperi@...> wrote: > > At 08:47 AM 11/07/2006, you wrote: > >The problem, it turned out after much investigation, was having the CKOPT > >fuse cleared. > > Which of course you are supposed have it programmed > for frequencies higher then 8MHz, but like many of > us forget to do it :( > > Regards > > John Samperi > > ******************************************************** > Ampertronics Pty. Ltd. > 11 Brokenwood Place Baulkham Hills, NSW 2153 AUSTRALIA > Tel. (02) 9674-6495 Fax (02) 9674-8745 > Email: john@... > Website http://www.ampertronics.com.au > *Electronic Design * Custom Products * Contract Assembly > ******************************************************** >