Yes, the termination resistors go only at the termination points to <hopefully> stop reflections on the transmission lines. They don't go at every node. DLC magzky02 wrote: > hello folks, > > I am using a micocontroller to communicate with 18 other > microcontrollers via rs489. Using the IC MAX3088, and a 100 ohm > resistor across A and B.. Since there are 19 MAX3088, there are also > 19 100 ohm in parallel. IS there something wrong with this? the > resulting resistance is only about 5.3 ohms. > > thanks for advice > > mago > > > > > Yahoo! Groups Links > > > -- ------------------------------------------------- Dennis Clark TTT Enterprises www.techtoystoday.com -------------------------------------------------
Message
Re: [AVR-Chat] rs485 communication
2007-04-12 by dlc
Attachments
- No local attachments were found for this message.