Nice soldering job - very tidy. I suppose that the real test of this modification would be how well two such systems track each other in real-time. Ceramic Resonators such as was originally mounted have +/- 0.5% accuracy. Crystal accuracy is typically +/-50ppm (100x better than the resonator), that means a worst-case error between 2 crystal oscillators of 100ppm. If you were using these to run a clock that equates to .36 seconds disagreement over an hour. To hit the 1ms accuracy that Gary quoted earlier you'd need to resynchronize such a system at least every 10 seconds minimum. So, while using a crystal doesn't eliminate the synchronization problem, it significantly reduces the effort required to do so and still maintain reasonable accuracy. Eric --- djbrow54 <davebr@...> wrote: > Success! I had a tech at work take off the > resonator. I added the > capacitors (0302, I think) and a through-hole > crystal. Man were those > capacitors small! Rock solid performance! Photo > "AtomPro28 crystal. > jpg" is in the Files>BasicAtomPro>Original PSIM>Dave > Brown folder. ____________________________________________________________________________________ Need Mail bonding? Go to the Yahoo! Mail Q&A for great tips from Yahoo! Answers users. http://answers.yahoo.com/dir/?link=list&sid=396546091
Message
Re: [ComputerVoltageSources] Re: DIY gonzo tactics
2007-01-28 by Eric Brombaugh
Attachments
- No local attachments were found for this message.