Yahoo Groups archive

Digital BW, The Print

Index last updated: 2026-04-28 22:56 UTC

Message

Re: [Digital BW] Eboni v1.1 - Dmax - Problem

2016-01-30 by phlg@...

Thank Paul.

I will contact MIS.


I printed more ramps this morning, quickly dried at the same time. The differences are slightly lower my previous comparisons but still high, too high to match.


Below, the measures of the K ramps :



Canson Rag – Eboni v1.0 :


Gray LAB_L

0.00 97.58

5.00 70.90

10.00 55.17

15.00 44.32

20.00 36.43

25.00 30.58

30.00 26.84

35.00 23.14

40.00 20.29

45.00 19.22

50.00 18.17

55.00 17.43

60.00 16.97

65.00 16.49

70.00 16.36

75.00 16.16

80.00 15.99

85.00 15.92

90.00 16.01

95.00 16.05

100.00 15.97




Canson Rag – Eboni v1.1 :


Gray LAB_L

0.00 97.79

5.00 76.24

10.00 63.31

15.00 53.82

20.00 46.38

25.00 40.53

30.00 36.35

35.00 31.95

40.00 28.47

45.00 26.52

50.00 24.02

55.00 22.67

60.00 21.29

65.00 20.05

70.00 19.56

75.00 18.95

80.00 18.55

85.00 18.32

90.00 18.30

95.00 18.37

100.00 18.18




Epson HPN – Eboni v1.0


Gray LAB_L

0.00 96.91

5.00 61.49

10.00 45.45

15.00 35.39

20.00 28.43

25.00 24.26

30.00 20.30

35.00 17.53

40.00 15.61

45.00 14.82

50.00 13.99

55.00 13.60

60.00 13.27

65.00 13.18

70.00 13.14

75.00 13.31

80.00 13.32

85.00 13.43

90.00 13.61

95.00 13.88

100.00 13.96



Epson HPN – Eboni v1.1


Gray LAB_L

0.00 96.97

5.00 67.17

10.00 52.20

15.00 41.57

20.00 34.90

25.00 30.05

30.00 27.60

35.00 23.36

40.00 21.12

45.00 19.84

50.00 18.61

55.00 17.50

60.00 17.03

65.00 16.31

70.00 16.28

75.00 15.74

80.00 15.42

85.00 15.18

90.00 15.35

95.00 15.21

100.00 14.92




Attachments