[Digital BW] 1290 MIS VM curves problem

2002-09-21 by Paul Roark

scrber [stephen.bate@...] wrote:

>... MIS VM hextone set for the Epson 1290 (with Paul's new curves).
>... printed the 21 step wedge on EAM and have found the following:

>cool : Nicely separated, seems very even and just what I'd expect.

>NC : as above

>Warm : yikes.  There is a huge separation between the 75 and 80
>steps,...

That is where the steep toner curve starts.  Other 1290s seem to handle it
well.  So, your machine might be slightly off or something in your settings
may be different.  Before, tweaking the curve, I'd re-check the settings.

> There are no smooth graduations between midtones (all of
>which seem extremely light) and the shadows - for sure this is not a
>smooth ramp.

Now it is sounding like the cyan (main midtone) was missing.  Be sure to do
a nozzle check.  However, if the cyan ink(s) are not firing right, none of
the curves would print well.

I'd check the rest of the system before tweaking any curves.  Also, I'll
send you curves off list just in case the warm curve that MIS posted is
corrupted.


Paul
http://www.PaulRoark.com