A status report, just in case this was keeping anyone up nights: > I just switched my 1280 from MIS VM to MIS UT-2/Eboni, using a new, > prefilled set of MIS CFS carts & tubes. I cannot get clean nozzle > checks. I did windex-on-pad, windex-under-head, > windex-nozzle-injection, MIS's de-foaming procedure, several cycles of > 3 cleaning passes followed by three purge prints. For my labors, one > color is now not printing at all, and the black cart just squirts ink > on the edge of the page. I must be doing SOMETHING wrong!? I finally contacted MIS, and they immediately sent me a new prefilled cart & tube set, which solved the problem. Finally! They're examining the old one to find out what the problem was, presumably to keep it from happening again. Thanks, everyone at MIS -- excellent customer service! Harry
Message
Re: 1280 / CFS nightmare
2004-02-16 by Harry Saddler