Re: QTR UT2 calibration

2004-05-21 by Roy Harrington

--- In DigitalBlackandWhiteThePrint@yahoogroups.com, "px3n120x" 
<px3n120x@y...> wrote:
> --- In DigitalBlackandWhiteThePrint@yahoogroups.com, "Roy Harrington" 
<roy@h...> 
> wrote:
> > --- In DigitalBlackandWhiteThePrint@yahoogroups.com, "px3n120x" 
<px3n120x@y...> 
> > wrote:
> > > Just switched from UT to UT2 and am having a hard time calibrating a profile 
for QTR.
> > > The problem is that when printing the calibration page instead of having a 
bend for 
> > each 
> > > color, all the bands have mixed colors including sepia and the blue.
> > > I'm using the latest QTR (b9). Is this technique not valid with UT2 inks?
> > 
> > It sounds like either you are using the wrong file -- the one for beta9 is
> > inkseparation.psd, an RGB file -- or you must the QuadTone Calibration
> > in the print dialog.
> 
> I'm doing all of the above correctly.
> 
> > 
> > BTW, I'm not sure which printer you have but did you try the UT2 profiles
> > on the website?
> 
> I have an Epson 1280 and just tested with a profile downloaded from your site and 
it 
> works fine. Never had this before I changed inks and am sure it has nothing to do 
with the 
> inks. Your instructions (and my memory) say to just edit calibration=yes and set 
the 
> default_ink_limit to 100. Choose QuadTone Calibration in the menu and select the 
profile I 
> just created.
> 
> Andu
> > 
> > Roy


I'm not sure I understand that last paragraph  "it works fine".  What
works and what doesn't??

But anyway, the other thing idea is: are you applying a profile in PS?   When
you Print with Preview -- the bottom under Color Management should NOT
have Proof set, and Profile should say Same As Source.

Also for the profile edits I assume you are using upper case and you are
re-running Run-Quad-Profile.  The profile should end up with a 
name ending in "calib".