Re: [Digital BW] MIS VM Quad problems

2001-11-01 by Colin Anderson

----- Original Message -----
From: "Paul Roark" <paul.roark@...>
To: "DigitalB&WPrint" <DigitalBlackandWhiteThePrint@yahoogroups.com>
Sent: Thursday, November 01, 2001 3:39 AM
Subject: [Digital BW] MIS VM Quad problems
>
> If you want to start modifying the curves, print the 21-step test file to
> see exactly where the problems are.  Then open the curve in question and
> move the points where the problem is in the appropriate direction.  I
always
> use the 0-256 (8-bit) scale, instead of the 0-100% ink scale, in order to
> have better control.  The cyan curve is the one that gives the best
control
> in the midtones.  Move the point about 3 units for each 1% that the
21-step
> test print is off by.

Paul,

Which way should one move it? Also, the curves on my system are split into
RGB not CMYK.

Cheers,
Colin