Yahoo Groups archive

Digital BW, The Print

Index last updated: 2026-04-28 22:56 UTC

Message

Re: Linearizing a QTR Curve

2005-02-21 by Roy Harrington

--- In DigitalBlackandWhiteThePrint@yahoogroups.com, "Tom Husband" 
<thusband@s...> wrote:
> 
> I'm at the point of entering densities from the 21 step wedge and am
> using a scanner and PS CS to measure.  I've set the second info
> palette to LAB but when moving over the each density it only shows
> whole numbers and no decimal point in "L".  All the other QTR curves
> are out to three decimal places.  Is there a way to get PS CS to read
> that way?  I must be missing something.
> 
> Thanks,
> 
> Tom

As Louis said, integer values are probably good enough.  But there are
a couple ways to coax a little more precision out of PS.   One is that
you can use RGB values -- at least they go 0-255 instead of 0-100.
Also if you have scanned 16-bit the Info palette has a 16 bit mode 
where the L values show 0-32768.

Roy