2005-10-26 by Steve Kale

BTW I think the below may be fine for the PCS to Device (B2A0) tag since we
are just applying a simple transfer function to a single channel,ie to
luminance only, and BPC can be built into this transform.  I wonder, though,
if it creates complications on the soft proof leg, Device to PCS (A2B0),
because it will be this tag (I assume) that PS coordinates with most for
soft proofing. 


> From: Steve Kale <stevekale@...>

> In addition, Roy seems to only use the
> Out Curve part of the A2B0/B2A0 tags which would make sense as an easier
> application because we are just applying transfer curves.  I have never seen
> a colour profile use this portion of the tag.