I recently made a new profile for the 2400, UT-3D inkset, and Crane SR paper. I was curious how the ColorVision spectro and my older X-Rite DTP22 compared with respect to their Lab A & B measurements. The graph (if it gets through the Yahoo filter) and numbers below show the results for 5 points (dmax, 75%, 50%, 25%, and paper white). "CV" is for ColorVision; XR for X-Rite. In a different comparison, an Eye-one was about like one of the meters for Lab A and about like the other for Lab B. I suspect this type of accuracy is all we can expect from these price points, unfortunately. L CV-A CV-B XR-A XR-B 3.94 -0.42 -1 -0.46 -1.1 25.39 0.7 0.8 -0.02 1.24 51.64 0.98 1.17 -0.01 1.76 73.76 1.14 1.16 0.08 1.97 96.22 0.82 0.72 -0.24 1.94 Paul www.PaulRoark.com <http://www.paulroark.com/> [Non-text portions of this message have been removed]
Message
ColorVision spectro v. X-Rite DTP22
2006-08-05 by Paul Roark
Attachments