Re: Houston, I have a problem :(

2008-08-01 by pr_roark

> Double check if you got the right inksets. 
> ... you might have mix-up;  MIS inks are Eboni-6 and 
> K6 [is] from Cone. 
>...I think MIS/Paul Roark have not release any QTR's
> profiles for 1400 yet.

QTR v. 2.6.1 has 1400 black only profiles.  I use the Epson driver for 
the Eboni-6 inkset in the 1400.

Be sure the nozzle check is perfect.  

The ink density order should be, from darkest to lightest: K, C, M, LC, 
LM, Y.  You can print a QTR Calibration Mode print to check this ink 
order.

Paul
www.PaulRoark.com