Yahoo Groups archive

Digital BW, The Print

Index last updated: 2026-04-28 22:56 UTC

Message

Re: [Digital BW] Poor man's densitometer

2009-01-15 by kwalsh74

> 1.  Instead of applying Gaussian Blur to the steps before taking 
> measurements, try the Blur Average and clean up any dust first.

Excellent suggestion.  Just did this with another paper I was
calibrating this evening.  Fussiness of moving around the selection
rectangle and hitting Ctrl-F to do the average filter was more than made
up for in the ease of reading off the L values after doing this.  Thanks!

> 3.  If you are trying to determine the reflection densities of the
> output based on the Stouffer, it is only valid if the density range 
> of the output falls within the range of the Stouffer, which goes up 
> to Log 2.0.

I'm only doing matte papers, so none of them can get up to 2.0 anyway!

Thanks for the tips!