Re: Help! QTR LINEARIZE confusion

2009-05-19 by pr_roark

"t_j_l_s" <tls@...> wrote:
>
> I've been asking about this in the QuadtoneRIP group but no answers. :-(

I put a link to a brief description of how I use the PrintFixPro spectro on the forum.  The workflow description is at http://www.paulroark.com/BW-Info/Spectro.pdf

>... SpyderPrint wants to emit density values when in 
> "QTR" output mode.

I don't use the "QTR" output mode.
 
> 2: I can't find any good documentation of what the BOOST_K 
> option does or when or whether to use it.

It puts a steep slope on the K curve from the other ink limit curve to the new K limit.  I find QTR's K curve usually has enough of a slope on it so the black boost is not needed.  It allows you to try a higher K limit, however, without messing up the rest of the profile.

> I notice I'm getting maximum densities of about 2 while 
> others report Dmax for this paper around 2.3.  

A quick way to find the best dmax is to print a 21-step test strip with a QTR profile that simply has a straight line from (0,0) to (100,100) for K, with all other inks not used.  To make the straight line curve, go to the Curve Creator, scroll down in the Black (K) box to Load Curve, then hit the Curve button.  Click on the Point List tab.  Then just enter the coordinates noted above.  The curve preview should show a straight line.  I name these curves "K-0-100." 

Hope this helps.

Paul
www.PaulRoark.com