Dieter, thank you for your response. I was indeed looking to have the 155 move to step 1 on initiation and I currently manually set it to 8 to achieve this. I was just curious about a labour saving mod. I quess I'll have to save my pennies to buy an A 154. Danke, Stuadh --- In Doepfer_a100@yahoogroups.com, <hardware@...> wrote: > > Stuadh > > No. A hardware counter (CD4024) is used in the A-155 (no microcontroller) > for address generation. The positive transition at the reset input of this > circuit causes to set all addresses to zero. > > > Hi, > > > > is it possible to mod an A-155 to reset to step 8 rather than 1? > > No. A hardware counter (CD4024) is used in the A-155 (no microcontroller) > for address generation. The positive transition at the reset input of this > circuit causes to set all addresses to zero. > > But I can't see a reason to reset to step 8. If you simply "re-define" the > steps in your sequence (1->8, 2->1, 3->2 ...) you are able obtain the same > result. Or did I overlook anything ? > > Best wishes > Dieter Doepfer > > P.S. The A-155 in combination with A-154 has a different behaviour. A reset > signal does not set to step one but only prepares the unit to jump to step > one with the next clock pulse. Maybe this is the behaviour you want to have. > > > > > Yours Aye > > > > Stuadh > > > > > > > > > > > > > > Yahoo! Groups Links > > > > > > > > > > > > >
Message
Re: A 155 Mod request
2006-10-09 by stuadh
Attachments