Re: ASys and Doepfer Cable Layout, was RE: [Doepfer_a100] modular c oncepts. . .

2002-03-28 by electricbeats_eof

Thank you...


-klaus

--- In Doepfer_a100@y..., "Rhen, Kris" <krhen@s...> wrote:
> > To Kris:
> > Thank's for the practical tip on the spacing,  if you could 
> > supply me with some 
> > wiring diagrams that would be awesome... you can do this off 
> > list if noone else needs them ..
> 
> You're welcome.  I'll send it to the list as it may be useful in the
> archives.  Basically, the ASys looks like this:
> 
>    GND     +12v    +5v     -12v
> # 0   0 | 0   0 | 0   0 | 0   0
> #
> # 0   0 | 0   0 | 0   0 | 0   0
> 
> 
> grouped in fours (note sure which end the red cable stripe goes on 
because
> I've never used them in an ASys frame), and are marked well on the 
PCBs (at
> least that I have)
> 
> 
> Doeper and ASol is (from RED STRIPE ON CABLE TO LEFT - TYPICALLY 
DOWN TOWARD
> BOTTOM OF PCB - DOEPFER CONVENTION)
> 
>                                 INTERNAL  
>   -12v      GND     +12v  +5v   CV GATE (not connected)
> #   O  | O   O   O |  O  | O  | O   O
> #   O  | O   O   O |  O  | O  | O   O
> 
> 16-pin version.  There is also a 10-pin version that leaves off the 
pins
> from +5v to the end with the INTERNAL GATE.  They're standard 
dual .1"
> spacing headers.  NOTE that many ASys (and ASol) need the +5v lines 
so some
> care must be taken with the Doepfer power supplies and 5v 
converters etc.
> Some ASys modules really suck juice (The RS360 Vocal Filter I was 
told takes
> 270mA itself!  NOTE also there are NO specs on their website 
concerning
> their module current draw.  Put mine in the doep case and 
immediately blew
> the fuse - and had to mount another supply in the case and split 
the bus to
> get things powered :-(
> KRIS
> 
> 