Hello Simon, we're entering territory where we risk to get lost in the Doepferian outback... I could be *wrong* however I'd choose the correct fuse for the device in question: the PSU2. Since you will not fuse the mains supply and the transformer likely got his own fuse this makes sense to me. Regards, Ingo --- In Doepfer_a100@yahoogroups.com, "beakanddune" <beakanddune@...> wrote: > > Thanks for your help Ingo. I hadn't noticed this info on the FAQ page. > From this info it seems I should be using a slow blow fuse in the > range 630-800mA. But is this correct.....? > > ....while I was searching for 800mA fuses (anything other than 500mA > or 1A is very hard to find in Australia), I noticed that that fuses > are rated for voltage. As I'm in Australia the fuses I'm finding are > rated at 240VAC. Given that I'm using a step down transformer for my > 110v PSU2, should I be using an 800mA fuse thats rated at 110VAC ? > Could the fact that i'm using 500mA 240VAC fuses in a 110V PSU2 be > causing me my problem ? Sorry for my ignorance on all this :-( > > > --- In Doepfer_a100@yahoogroups.com, "ilanode" <techmeier@> wrote: > > > > Hello Simon, even though you might have damaged one or more modules I > > don't think this is the reason for the constantly blowing fuses. > > > > Assumed by now all modules are connected correctly I suggest to try > > other fuses: "630 - 700 mA time lag (slow blow)". [That info is from > > Dopefer's HP -> FAQ.] Make sure they are SLOW BLOW/TIME LAG! > > > > Hope that helps, Ingo > > > > --- In Doepfer_a100@yahoogroups.com, "beakanddune" <beakanddune@> > > wrote: > > > > > > Hi People, > > > > > > I know that the topic of fuses has appeared a few times and others > > > have experienced similar problems but I'm not sure what to do about > > > this. Sorry about the long winded nature of the post but I don't want > > > to leave out any prudent info (including details of my own stupidity). > > > > > > I have an A-100P with a 110v PSU2. I'm in Australia so I'm using a > > > stepdown transformer that has a 250 VA rating. The A-100P is half full > > > and has been operating for the last month or so without a problem. I > > > recently added an A-118 (Noise) and an A-131 (VCA) and had no > problems. > > > > > > The other day I removed a few modules in order to fit the spring from > > > my A-199 and when putting the modules back in I accidentally plugged > > > my A-112 in incorrectly (I plugged the cable into the bus board > > > without plugging it into the left hand row of pins). When I powered > > > the unit on the lights came on momentarily and then no power. I then > > > realied my error and corrected it but it seems that the fuse in my > > > case had also blown. I replaced this with a 500mA time lag fuse and > > > this worked fine. > > > > > > Since then when I power the case on the fuse blows 80% of the time and > > > I've just run out of 500mA fuses. :-( Note that 1A fuses seem to > > > work fine but I'm aware that these are not recommended. > > > > > > I'm not sure whether this problem is being caused by : > > > > > > a. A now 'damaged' A-112 (still seems to work ok). > > > b. A damaged PSU2. > > > c. Unsuitable fuses. > > > d. Some other factor. > > > > > > Could anyone tell me whether I've likely broken anything and if there > > > is anything that could be causing the fuses to blow ? > > > > > > Thanks in advance > > > > > > Simon > > > > > >
Message
Re: Fuse Problems
2007-07-21 by ilanode
Attachments
- No local attachments were found for this message.