2007-10-23 by hardware@doepfer.de

> A have an A-155 that used to be connected to an A-154. I have re-
> attached the ribbon cable to ST2 and the busboard connection to ST1.
> The A-155 powers up, but it will only address steps 2 and 4. What is
> the problem here?
>
> Thanks in advance,
>
> Matt

Difficult to diagnose. If the cables are connected in the right way (not
reverse, not displaced) the A-155 is probably defective and has to be
repaired.  I'd suppose the problem is the counter circuit on the small
control board that generates the addresses (CD4024).

Best wishes