Hi Bryan, > I'm rather new to oscilloscopes and I was wondering should I expect it to be able to tell me the frequency of a slow-moving CV. I'm not seeing a way to read the frequency of a wave. As long as your slow-moving CV is actually repetitive, then you should be able to do it by measuring the time it takes for the pattern to repeat. I don't know what facilities that scope has, but often scopes have cursors you can move around the screen, and it will tell you the readings of where they are, and then take the difference. If not, then you will have to judge it for yourself, from the timebase setting of 'so many seconds per division'. Do this at two points where the pattern repeats, for example the peaks, or where the wavefrom crosses the zero line *in the same direction*: this is called the 'period' of the signal. Then simply divide this into 1 to get the frequency, so frequency = 1/period. Try it on something you know first, to check that you have the hang of it, for example, for middle C coming out of one of your oscillators you should see the time difference as about 0.0038 seconds = 3.8 milliseconds, so 1/0.0038 = 263Hz (middle C actually 261.63Hz). For a slow moving waveform it is likely that you will have to 'freeze' the display after one pass to be able to make a measurement if the timebase is set very slow. Tim
Message
Re: Frequency reading on an oscilloscope?
2007-10-30 by Tim Stinchcombe
Attachments