I decided to try a number of signals patched to my A150's I/O2 (Normally Open) jack. I wanted to see which ones would trigger an ADSR envelope by bleeding through the O/I jack, even though nothing was patched to the A150's CV jack to close the switch. Signals that DID NOT bleed through were: A145 LFO Pulse A147 LFO Pulse A155 Trigger A156 Trigger A190 Clock A191 LFO Pulse Signals that DID bleed through were: A155 Gate A160 Clock Divider A162 Trigger Delay A165 Trigger Modifier A190 Gate What's even more worrysome is that I'm fairly sure that I've successfully switched an A190 Gate signal with the A150 in the past, so now I'm concerned that the A150 is actually deteriorating in this regard. I wish I could be more certain about this. There was an earlier response from Dieter on this issue, in which he ascribed the problem to user abuse of the A150. I'm certain that he misunderstood the symptoms, though, because he was talking about signals patched to the CV input, rather than the switch inputs. In any case, in was in the middle of preparations for the Frankfurt show and he probably didn't give the issue a lot of attention. I've sent a copy of this post directly to Doepfer by email. Joe