A-164-1 and A-185-2 problems

2007-12-30 by Frequency Divider

Hi Group, Dieter,

I just tested the new modules I got this week and I'm sorry to say that 
twice I got some unexpected behaviour. The 3rd button of the Manual Gate 
does not seem to generate a signal. Button 1 and 2 are ok, no sign of 
any physical damage, the sticker on the back says 'vortest', perhaps 
that's a clue?

Also the Precision Adder is default connected to the bus board (it 
immediately influenced the pitch of the a-111's that are in the same 
case) but this is not the behaviour I want, because there's also an 
a-190 in the same case, so I will need to adjust a jumper setting, but I 
think there's not yet any exact information about this on the website.

This last problem seems more serious because of the warning for possible 
short circuit in the a-185-2 text. I have not tried to do any further 
testing as I have an a-190 in the same case. Especially new users could 
maybe get into trouble if this happens to them and they are not aware? 
Or am I getting paranoid now?

I do like the new jack sockets by the way

Anyway, greetings and happy 2008

Anton