> That's definitely a prototype (probably the very first one from 1993) > because in the production series all potentiometers were pcb mounted. Even > the later prototypes had pcb mounted potentiometers. It will be a problem to > identify the trimming potentiometers as the positions and values may have > been changed compared to the final version that is described in the service > manual. I'm sorry but we have no records of this prototype as it's about 15 > years ago (the MS-404 has been developed in 1993). Well, I suppose that makes it a collectable! I've just had another fiddle with it and noticed the screw trimmer accessed through the hole in the back of the case, the MIDI to CV scaling I believe, and this has let me fix it. I don't think I've got it set exactly right but at least it is not playing 13 semitones to the octave now! Giles
Message
Re: AW: [Doepfer_a100] MS404 VCO scale setting
2008-02-14 by Giles Ward
Attachments
- No local attachments were found for this message.