Stuadh, I'll send the adjustment procedure to your email address as pdf attachment. It seems that P4 has to be readjusted. Best wishes Dieter Doepfer > -----Ursprüngliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von stuadh > Gesendet: Dienstag, 15. Juli 2008 22:10 > An: Doepfer_a100@yahoogroups.com > Betreff: [Doepfer_a100] Re: Quantizer Calibration > > > Dear Dieter, > > I now have the Quantizers back from the shop, but they are still > out. Both scales (All) track accurately (using a MIDI Keyboard and > Kenton Pro 2000 as the CV source) but the CV outs change at the wrong > points when in chord or quint. For example, on one, the major chord > flips on the root, the third and the sixth (not the fifth). Also, the > output of one quantizer is almost one semitone below the other (all > other things in the signal path being the same). > > To this end, I need to try myself. Based on the Version 1 board and > with respect to your instructions, below, can you explain where P1, > P2, P3 and P4 are, please. > > Next to the TL062CN chip = P > The small Pot next to IC6 = P > The pot (of the pair) closest to the CV and Trig out Sockets = P > The pot (of the pair) closest to TS274CN chip = P > > Many thanks, > > Stuadh > > > > > > > > > > Yours Aye > > > > > > Stuadh > > > > Short form: > > > > The scale of the CV outputs is adjusted by P4 (one potentiometer for > both > > outputs). E.g. an A-176 can be used to generate a manually controlled CV > > input voltage for the A-156. When the corresponding CV input voltage is > > increased the CV out has to change according to the setting of the > > quantization switches. The easiest is to use the quint setting and then > > check the octave intervals which have to be exactly 1.00V. > > > > The scale inputs are adjusted P1 (CV In 1), P2 (CV In 2) and P3 > (Transpose > > CV In). E.g. an A-176 can be used to generate the corresponding CV input > > voltage. The voltage output of the A-176 can be set to a multiple of > 1.00V > > (e.g. 4.00V or 5.00V) and the voltage has to be measured > simultaneously e.g. > > by a digital multimeter. P1 (or P2 or P3) has to be adjusted so that the > > corresponding CV output reads the same voltage as the input (i.e. > 4.00V or > > 5.00V). The finest quantization (semitone) has to be used for this > > adjustment. Otherwise the steps are too coarse for this adjustment. > > > > Best wishes > > Dieter Doepfer > > > > > > ------------------------------------ > > Yahoo! Groups Links > > > [Non-text portions of this message have been removed]
Message
AW: [Doepfer_a100] Re: Quantizer Calibration
2008-07-16 by hardware@doepfer.de
Attachments
- No local attachments were found for this message.