AW: [Doepfer_a100] a188-2 cv range problem

2009-01-12 by yahoo@doepfer.de

> hi group,
>
> can anyone suggest a way to increase the range of the cv2 input of the
> a188-2 multitap bbd? it won't quite reach an octave/volt. this means i
> have to use cv1, which is slightly over an octave/volt, and i'm having
> to use up 8hp of valuable rackspace to attenuate it slightly.
>
> great module, though (thanks for the encouraging words, bakis).
>
> thanks in advance,
>
> stu

To increase the sensitivity of CV2 the value of R4 has to be reduced. R4
(47k) is located between the CV2 control and the clock socket. If you want
to change the scale the 25-turn trimming potentiometer P19 has to be
adjusted.

Best wishes