thanks dieter. is there a simple relationship between the value of r4 and cv2's sensitivity? i don't want to end up with a 0.3v/octave cv2 :) best, stu --- In Doepfer_a100@yahoogroups.com, <yahoo@...> wrote: > > > hi group, > > > > can anyone suggest a way to increase the range of the cv2 input of the > > a188-2 multitap bbd? it won't quite reach an octave/volt. this means i > > have to use cv1, which is slightly over an octave/volt, and i'm having > > to use up 8hp of valuable rackspace to attenuate it slightly. > > > > great module, though (thanks for the encouraging words, bakis). > > > > thanks in advance, > > > > stu > > To increase the sensitivity of CV2 the value of R4 has to be reduced. R4 > (47k) is located between the CV2 control and the clock socket. If you want > to change the scale the 25-turn trimming potentiometer P19 has to be > adjusted. > > Best wishes > Dieter Doepfer >