Re: [Doepfer_a100] A-185-1 Bus Access

2009-03-05 by Florian Anwander

Hello John

> But can the A-185 control 4 VCO's and 3 ENV's accurately all on one row? (If they fit on 1 row that is, not worked that out yet).
Yes. That is what this module is made for. See description:
"In general the A-185 is recommended as soon as more than 2 VCO's 
(A-110, A-111) are controlled by the same control voltage source. 
Without interconnection of the A-185 in this case tuning inaccuracies 
(scale) may occur. The A-185 is [read that like: should be] mounted 
close to the VCOs."

The envelopes have no trouble beeing connected to one gate bus.

Florian