Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: A-185-1 Bus Access

2009-03-05 by jmaddocks1975

Cheers guys, exactly what I need.
I can't access the doepfer website at work anymore so sorry for obvious question.

John :-)





--- In Doepfer_a100@yahoogroups.com, Florian Anwander <fanwander@...> wrote:
>
> Hello John
> 
> > But can the A-185 control 4 VCO's and 3 ENV's accurately all on one row? (If they fit on 1 row that is, not worked that out yet).
> Yes. That is what this module is made for. See description:
> "In general the A-185 is recommended as soon as more than 2 VCO's 
> (A-110, A-111) are controlled by the same control voltage source. 
> Without interconnection of the A-185 in this case tuning inaccuracies 
> (scale) may occur. The A-185 is [read that like: should be] mounted 
> close to the VCOs."
> 
> The envelopes have no trouble beeing connected to one gate bus.
> 
> Florian
>

Attachments

Move to quarantaine