Re:A100 miniature case and French Connection from AS.

2009-06-10 by zaum

> I think about buying a A100 miniature case wich I could use with my
> French Connection from AS.
> I think the perfect system for me is : AS RS 95e, A 143-9 QFLO, A124
> WASP FILTER, A132-1.
>
> I'd like to know if there is any restrictions with the AS module and
> the miniature case.

You are saying you already have a French Connection and you are  
thinking about the mini case system? Is that correct?

As mentioned, you do want to add up the power usage and compare to  
the mini psu.

You will need an adaptor ribbon cable to power the RS95e since the  
cable for RS is different than Doepfer

You probably need to drill the screw holes wider on the RS module  
because they use a different spacing from the edge of the module to  
the screw holes so you can easily mount a row of either Doepfer or  
ASys in either company's case because the strip with  but the two  
brands leave a gap if mounted next to each other and that adds up to  
a little less you actually can fit .  One alternative to drilling new  
holes, though I don't know if it works on the minicase is to remove  
the metal strip from the rail that has threaded screw holes in it and  
use nuts to hole the module screws in the rails instead.

You didn't mention if you have any other modules. What you have  
doesn't quite add up to a complete typical synth voice. You lack at  
least an envelope & VCA. Maybe you are aware already, you didn't  
mention your goal. If the smallness is a requirement and you do want  
a basic synth voice you might want to consider one of the "analog  
synth voices" in a single module that Doepfer or another module maker  
builds. For instance the just released Doepfer A-111-5 or the Cwejman  
VM-1 (if it fits in that case, I didn't check).