Thanks, I have an MX 224 (Analogue Solutions) in the chain after the Quantizer and/or VC Slew. It is clearly happening inside the VC Slews. --- In Doepfer_a100@yahoogroups.com, <yahoo@...> wrote: > > > I programmed a patch with my beautifully tuned VCOs, tonight. > > When I decided to use the A155 through a 156 to drive it, I > > noticed a significant voltage drop and I had to apply a voltage > > from the 176 to bring it back in tune with my other synth. Why > > should this be? > > > > I have also noticed that running the CV from the quantizer > > through either the dual or the VC Slew also caused a voltage > > droop, regardless of how low the slew setting is. > > > > Can anyone explain why this might be happening. > > I'd recommend to use one of the buffer modules A-185-1 or A-1185-2 if > several VCOs are controlled by the same CV source. These modules do not load > the source and include a buffer that is strong enough to drive several VCOs > without voltage drop. > > Best wishes > Dieter Doepfer >
Message
Re: Voltage droop when using a quantizer
2009-07-10 by stuadh
Attachments