> this voltage drop occurs with just one vco after one of the slew > limiters. > > since this keeps coming up, i think a note on the slew limiter > pages that additional modules are necessary would only be fair. > 90% of people who buy a slew limiter are expecting it to be > suitable for portamento. > > solving the problem would be even better :) > > cheers, > > stu Stu, you are right. We should add a corresponding note to the slew limiter manuals. For the A-170 the design has been changed already and the new version of A-170 includes buffers at the outputs (same as A-185-1/2). So far only a few modules of the new version have been delivered as they are manufactured since May 2009. They can be identified by the addition "Version 2" on the pcb silk screen (near the upper LED pair). For the A-171 the revision is on our to-do list. Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] Re: Voltage droop when using a quantizer
2009-07-13 by yahoo@doepfer.de
Attachments