> I've had a Quantizer from new, and I've just had a 2nd hand one > repaired by Doepfer, themselves. Why are they both completely > out of whack? > > Neither tracks 1V/Oct (I played it in concert with my Midi > keyboard) and the Voltages jump at different times. They are > also out of tune with each other. This happens using a buffer or > when driving a single VCO. This renders them unusable. > > Can I do anything to fix them? You find the adjustment procedure on our website: www.doepfer.de/service/a156_adjustment.pdf (English) www.doepfer.de/service/a156_abgleich.pdf (German) I'd recommend to measure the output voltages of the A-156 CV outputs before you start to adjust the module. Maybe it's not the A-156 which causes the problems. Select Major or Minor/Quint/- (not +6 or +7) at the A-156. Then increase the CV input voltage starting from zero (e.g. from an A-176 or a stopped A-155). The output should read 0.00V/0.58V/1.00V/1.58V/2.00V/2.58V and so on. If there is an zero offset (e.g. 0.02V output with 0V input you have to add this offset to each value (e.g. 0.02/0.60/1.02/1.60/2.02 and so on). Best wishes Dieter Doepfer