Hi Ben, I had the same trouble. My set up was: Multiples in top left corner, then 4 VCO's, if I put the CV into the multiples all 4 VCO's tracked. But if I put the CV into a VCO then only the VCO's on the right of that would track (make sense?) After some help from members of this site I tried different cables but still same problem so I moved the multiples and VCO's 8hp across and put a slew limitre module in the top left corner, problem solved!! The CV is definetly getting to the CV bus board, question is how!? try the following: Put the A-111 on the top row (connected to CV bus 1), and the A-110 on the bottom row (connected to CV bus 2). I know it's not practical but does it still track? Also just a thought, send a gate signal to the multiples, do the Envelopes trigger? Hope it helps John --- In Doepfer_a100@y..., "kali_the_black" <poictesme@e...> wrote: > I'm having a strange thing happening maybe you guys (and girls if > there are any out there) can help me... > > Here's the patch... a-111 -> vca -> vc mixer -> out. > > when I send a cv signal to my a-110 cv1 input via the a-180 multiple > the a-111 tracks! The a-111 does not track when the cv signal is sent > directly to the a-110 cv1 input. > > In a similar phenomenon the a-111 tracks when I input an lfo to the > cv1 input on the a-110 directly. > > why does it not track when I input control voltage directly to the a- > 110 cv1 input? > > To troubleshoot I changed out all of the cables (no change) and > removed the a-180 mult from the chasis (no change). I even tried > using different cables and connectors from my mcv4! I really want to > know how signal is getting to the system buss in some configurations > but not in others! > Help please! > Ben
Message
Re: strange cv happenings.
2002-07-30 by jmaddocks1975
Attachments
- No local attachments were found for this message.