> Hello again! > > Sorry to bother you all again...but I have another question. > I have a A-112 sampler module and I want to trigger it from a > Doepfer pitch ribbon (the pitch ribbon has the external R2M box). > The strange thing is that I can't seem to trigger the A-112 from > the ribbon... I can trigger the A-112 from e.g. a LFO, and from > the A-155 sequencer. I am suspecting that the ribbon controller > is delivering to low voltage (or that the A-112 wants slightly > more "juice"). The strange thing is that the ribbon works fine > with other modules... > Anyone with similar experience..? > Any good ideas...? Any simple way to adjust the A-112? > > Thanks, > > /Lars This issue has been discussed already in April 2008 in this group (startin a message dated April 27, 2008). You probably own an A-112 manufactured before May 2008. In April 2008 it came up in this group that the R2M/A-112 combo has problems with the gate transmission because the A-112 gate input had a 10k load that reduces the gate voltage coming from the R2M to about 2V. And that's not sufficient to trigger the A-112. All A-112 manufactured from May 2008 are equipped with a 100k resistor instead of 10k as we immediately changed the value of the corresponding resistor. If you are a bit familiar with electronics you may replace the 10k pull down resistor at the A-112 gate input to a higher value (e.g. 47k or 100k). It's the resistor R15 that is located just behind the Midi In socket (between Diode D5 and capacitor C21). Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] A-112 question
2010-07-19 by yahoo@doepfer.de
Attachments