ok well i got the scope out and used the frequency counter to measure from the resistors around the trim pots and found that i can tune each oscillator between 250-650 hertz. So at this point i just need to know what they should be tuned to. Can anyone help with this please Paul On 13 March 2011 16:54, phono 1337 <phono1337@gmail.com> wrote: > Is there any information on calibration for the A-117, I was given one > yesterday but it has been detuned off spec, so i would like to return it to > factory settings. > > regards > > Paul [Non-text portions of this message have been removed]
Message
Re: A-117 calibration
2011-03-14 by phono 1337
Attachments