> -----Ursprungliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von phono 1337 > Gesendet: Sonntag, 13. Marz 2011 17:55 > An: Doepfer_a100@yahoogroups.com > Betreff: [Doepfer_a100] A-117 calibration > > > Is there any information on calibration for the A-117, I was given one > yesterday but it has been detuned off spec, so i would like to > return it to > factory settings. > > regards > > Paul The two variable oscillators have to be adjusted to about 540 Hz and 800 Hz by means of the two trimming potentiometers. The oscillator signals are availabel on pin 4 and 6 of the CD40106. Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] A-117 calibration
2011-03-14 by yahoo@doepfer.de