Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: [Doepfer_a100] Re: What module i need to do that?

2011-07-20 by Florian Anwander

Am 20.07.2011 08:07, schrieb aletropdj:
> One A-162 Dual Trigger Delay?
> i think that, but i dont know can be controled by CV?
No, It can't.

First possibility: VC Triggerdelay. You need an A-171 VC slew limiter 
followed by an A-167 comparator (maybe the A-163 in OR-mode would work 
as replacement for the A-167 too).

Second possibility: unsymetric (more than 50%) pulse wave with trigger 
conversion.
Either: Use a A-110 or A-111 at very low frequency as clock and set the 
pulsewidth not symmetric. Send this pulse through an A-165 trigger modifier.
Or: Use any LFO saw wave, send it through an A-167 comparator, and set 
this to create an unsymetric pulse wave; again send this pulse wave 
through an A-165 trigger modifier.

Third possibility: The A-154 would do everything you want.

Florian