Am 20.07.2011 08:07, schrieb aletropdj: > One A-162 Dual Trigger Delay? > i think that, but i dont know can be controled by CV? No, It can't. First possibility: VC Triggerdelay. You need an A-171 VC slew limiter followed by an A-167 comparator (maybe the A-163 in OR-mode would work as replacement for the A-167 too). Second possibility: unsymetric (more than 50%) pulse wave with trigger conversion. Either: Use a A-110 or A-111 at very low frequency as clock and set the pulsewidth not symmetric. Send this pulse through an A-165 trigger modifier. Or: Use any LFO saw wave, send it through an A-167 comparator, and set this to create an unsymetric pulse wave; again send this pulse wave through an A-165 trigger modifier. Third possibility: The A-154 would do everything you want. Florian
Message
Re: [Doepfer_a100] Re: What module i need to do that?
2011-07-20 by Florian Anwander
Attachments
- No local attachments were found for this message.