2012-04-19 by Florian Anwander

Hello


> - some modules can pick-up the gate CV signal (e.g. A-140) [...]
This should read like
"some modules can pick-up the gate signal (e.g. A-140)"
The 140 does not use any CV


> - other modules may work as transmitter for the CV signal to the
>   bus ...
> - other modules may work as transmitter for the gate signal to
>   the bus ...
> - pay attention that only ONE transmitter for CV and ONE
>   transmitter for gate are allowed (otherwise modules may be damaged)
I don't feed gate or CV from any module to the bus. Instead I added a 
A-185-1 "Bus Access" to each row, so I can wire manually any source to 
the bus.

Florian

-- 