Not the clock signal but the reset signal triggers the reset, i.e. a positive voltage (not the rising slope !) at the reset input resets all A-160 outputs to zero and A-161 to step 1. The reset is static, i.e. as long as the reset signal is high all A-160 outputs remain low and A-161 stays at step 1 (even if clock pulses are present). Clock and reset are independent from each other for A-160/A-161 combo (in contrast to the A-154 where a reset signal triggers kind of a "wait state" and the actual reset is carried out at the next clock pulse that follows the reset). Best wishes Dieter Doepfer > -----Ursprungliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von Peter Sedin > Gesendet: Freitag, 3. Mai 2013 08:09 > An: doepfer_a100 > Betreff: [Doepfer_a100] a-160/161 question > > > At muff wiggler I read that the clock pulses does not reset the divisions after reset. > like in the picture.. why not??? > > > Mvh > > Peter H.K Sedin
Message
AW: [Doepfer_a100] a-160/161 question
2013-05-03 by yahoo@doepfer.de
Attachments
- No local attachments were found for this message.