Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: AW: [Doepfer_a100] HELP!! Malfunctioning 155, gig on Saturday!!!

2014-04-29 by Florian Anwander

Hello Mrak


you are writing:
"Im getting step 1 then step 2  three times THEN step 7 and 8.. "
can you reproduce this sequence (1,2,1,2,1,2,7,8) every time, or was it 
only an example?

Florian


On 29.04.14 21:56 , mark@markfrancombe.com wrote:
>
>
> Hey Deiter!
>
> Im afraid I tried you suggestion of the ribbon cable to the
> trigger/potentiometer boards, it all looks ok... I would have been
> surprised actually, It hasn't been moved in a while.
>
> So I think Ill have to go the "getting it fixed" route.
>
> BUT, I have to say, I guess mine is pretty old cos theres no sockets on
> the IC's.. all soldered in!
>
> Can I send it to you?
> (This time Im absolutely certain its broken- remember the last time I
> sent you something to fix the sampler, it wasn't broken!! )
>
> By the way, thank you so much for so promptly answering, I continue to
> find it totally amazing that you are so hands-on and customer oriented.
> Ive been trying to get a question out of Roland for a month now.
>
> Mark
>
>
>

Attachments

Move to quarantaine