> hi Joe, judging by the A190 manual, the A190 already has a divisor > built in and it also reponds to Program Change n. Hi ringmod Program Change isn't CV, though. I clock the A155 from the A190 all the time for midi sync, but when I want variable step length, I clock the A155 from the A147 VC LFO, and patch the A155 pre out back to the A147 to control the length of each step. You can't control the A190 divisor with a CV from the A155. The A154 clock generator, as I understand it, will work identically to the A147 for this purpose, with the exception that is also has PWM. I have two problems with this setup: No quantization of step length, and no midi sync. A VC divider would solve both of them, but as I mentioned, I'm not sure that the A163 will work correctly because it can't be reset when the master clock is reset. So, I'm back to where I started. Instead of a clock generator, I'd like the A154 to have a VC divider, with PWM. Joe
Message
Re: A163 as a clock divider
2002-11-11 by Joe Buechler
Attachments