Hello Dieter once again me... Am 19.11.2014 09:05, schrieb yahoo@doepfer.de [Doepfer_a100]: > A total different approach is to generate a CV from the rate of > trigger signals coming from the quantizer A-156. For this kind of a > frequency to voltage generator has to be patched, e.g. an A-162 > followed by a A-170 or A-171-2. The A-162 generates pulses with > constant length which are integrated by a slew limiter (nothing but a > 6dB low pass with very low frequency) to obtain a CV. This approach has the disadvantage that the voltage always will drop between two triggers. It will be like a sawtooth waveform; the lower the trigger rate is the more the voltage will look like a sawtooth. And the higher a change of rate is, the worse the slewlimiter will represent the change of rates. I think the counter based approach is more exact and it would not be that difficult to implement: simple CD4069 based clock oscillator, two stacked 4bit downcounters (4526) to create the 8bit value, and a resistor ladder D/A converter using buffers from the same 4069 as the clock oscillator, a TL062 as buffer, some resistors/caps around. Florian
Message
Re: [Doepfer_a100] Rate of change to CV and Cv change to gate
2014-11-19 by florian anwander
Attachments